AISIGINT GRIDFIT · GRID CONNECTION SCREENING

Drop a pin. See how that site connects to the grid.

GridFit is a grid connection screen for datacenter sites. From one location it maps the practical routes to the grid, gives an indicative time to power for each, and names the question to take to the utility. Tell us the MW and the date, and the answer is set against them.

Starts from one pinReviewed by our site teamMost reports in 1 working day

No site yet? Ask where to look, and we return numbered search areas for your load. Own the land? A Screen shows what it can be powered for.

GridFit map of a sample site south of Hyderabad, with the site pin, nearby substations and lines, and lettered routes to the grid
Sample pin · Hyderabad
© Google · © OpenStreetMap contributors
Routes from the pin
Time to power
The question to ask
A GridFit map for a sample pin south of Hyderabad
Why screen first

A map shows the grid. It does not show what the grid can power.

Most sites are chosen on land price and distance to a substation. The power date is discovered months later, after money has been spent. A Screen puts the grid question first, before the land is bought.

A nearby substation is not spare capacity.

Spare capacity is rarely published. A Screen says where it is unknown and separates what is mapped from what is confirmed.

The route sets the date.

Looping into a passing line, connecting at an existing substation and waiting for planned grid carry very different timelines.

Others want the same connection.

Datacenter campuses cluster. A Screen shows the datacenters already on record around the site.

What comes back

One pin in. A short answer out.

A Screen reads the grid around the pin and returns a report page with the map. Our datacenter site team reviews it before it reaches you, and every line names its source and its date.

Routes from the pin

Each practical route to the grid, lettered and drawn on the map, with its voltage and distance.

Indicative time to power

A month range for each route, set against your date when you give one.

Line cost band

An indicative cost range for the line on each route. Bays and your own substation come on top.

What feeds the substation

Where a nearby substation is fed from, and whether a published document flags loading there.

Datacenters nearby

Existing datacenters on record around the site, which depend on the same grid.

Two supplies

Which pair of routes could give the site two separate supplies.

The state rule

How that state treats the kind of connection each route needs.

The question to ask

The biggest unknown on the leading route, written as the question to put to the utility.

Inside a Screen

One site, a shortlist, or no site yet.

The same screen works at three scales. The map is a real GridFit view of Hyderabad. The charts are illustrative.

SITE REPORT · ROUTE OPTIONSILLUSTRATIVE EXAMPLE100 MW of IT load, needed by 202912243648MONTHS TO POWERAExisting substation220 kV · 2.5 km24-30BLoop into a nearby line220 kV · 4 km24-36CPlanned substation400 kV · 12 km36-48NEEDED BYRoute A is the route to pursue first. Each route names the next check to make.
Site report · routes against your date

Screen one site.

Each route carries a month range. Give a date and the report shows which routes can meet it, and which one to pursue first.

EVERY SCREEN · THE SHORT ANSWERILLUSTRATIVE EXAMPLEThree lines to read first1BEST FIRST ROUTERoute A, the existing 220 kV substation 2.5 km away.Its usual range sits inside your date.2POSSIBLE TWO SUPPLIESRoutes A and B, from two separate connection points.Whether they share a source upstream is the next thing to check.3BIGGEST UNKNOWNLoading and spare bays at the substation.Not published, so the report names the question to ask.Screening, not a connection offer. Each line links to its evidence.
The short answer

Read the answer first.

Every Screen opens with a short answer. The best first route, a possible pair for two supplies and the biggest unknown, each with the question to ask.

GridFit map of Hyderabad with numbered search areas around the substations that could serve a new datacenter load
Where to look · Hyderabad
© Google · © OpenStreetMap contributors
Where to look · numbered search areas

Search before you have a site.

With no site yet, GridFit numbers the areas around the substations that could serve the load. Land search starts where power may be possible.

COMPARISON REPORT · RANKED SHORTLISTILLUSTRATIVE EXAMPLEFive candidate sites, one brief#SITEGRID ROUTEMONTHSFLAG1Site C220 kV substation, 2.5 km24-30Clear2Site A220 kV line loop-in, 4 km24-36Flood edge3Site E132 kV substation, 1 km18-30Phase 1 only4Site B400 kV substation, 12 km36-48Late for 20295Site D220 kV substation, 6 kmNot ratedTight substationRECOMMENDED FOR AUDITSite C. The only site with a full route inside the 2029 date.
Comparison report · a ranked shortlist

Rank a shortlist.

Several pins compared for the same load and date. You see which sites are worth an Audit and which to set aside.

Screen boundary

A Screen guides the next check. It is not a connection offer.

A Screen is a desktop check. Distances are straight-line, time and cost are indicative ranges, and the utility confirms capacity, bays and dates. The topics listed here sit outside a Screen and are covered in the Audit.

See what the Audit covers
  • Land records and buildability
  • MW fit and campus layout
  • Water balance and cooling
  • Approval matrix and durations
  • Capex, NPV, IRR and payback
  • GO / CAUTION / NO-GO decision signal

Send us a pin.

A location is enough to start. Add the MW and the date you need power, and the report is set against them. Most site reports come back within one working day.